| Model | CLG-150 |
| Series | CLG-150-12 |
| Output | Dc Voltage | 12V |
| CONSTANT CURRENT REGION Note.7 | 9 ~ 12V |
| Rated Current Note.5 | 11A |
| Rated Power Note.5 | 132W |
| Ripple&Noise(max) Note.2 | 150mVp-p |
| Voltage ADJ.Range | 9 ~ 13V |
| CURRENT ADJ. RANGE | 5.5 ~ 11A |
| Voltage Tolerance Note.3 | ±2.0% |
| Line Regulation | ±0.5% |
| Load Regulation | ±1.0% |
| Setup,Rise Time | 3000ms, 80ms / 115VAC Â Â Â Â Â 500ms, 80ms / 230VAC at full load |
| HOLD UP TIME (Typ.) | 50ms / 230VAC Â Â Â Â Â 16ms / 115VAC at full load |
| Input | Voltage Range Note.4 | 90 ~ 295VAC Â Â Â Â Â 127 ~ 417VDC |
| Frequency Range | 47-63Hz |
| Efficiency(typ.) | 88% |
| Ac Current(typ.) | 2A/115VAC Â Â 1A/230VAC Â Â 0.68A/277VAC |
| Inrush current(typ.) | COLD START 65A(twidth=595μs measured at 50% Ipeak) at 230VAC |
| leakage Current | <1mA / 240VAC |
| Protection | Over Current(typ.) | 95 ~ 108%
 Protection type : Constant current limiting, recovers automatically after fault condition is removed |
| Over Voltage | 13.5 ~ 17V |
| Protection type : Shut down and latch off o/p voltage, re-power on to recover |
| Environment | Working Temp | -30 ~ +70℃ (Refer to "Derating Curve") |
| Working Humidity | 20-95%rh non-condesing |
| Storage Temp,Humidity | -40~+85 , 10~95% RH |
| Temp.Coefficient | ±0.03%°c(0-50°c) |
| Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| Safety&EMC | Safety Standard | UL879, UL8750, UL1310, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V),
CSA C22.2 No. 250.0-08(except for 48V), CSA C22.2 No. 207-M89(except for 48V), IP67, J61347-1, J61347-2-13 approved |
| Withstand Voltage | I/P-O/P:3.75KVAC Â Â I/P-FG:2KVAC Â Â O/P-FG:0.5KVAC |
| Isolation Resistance | I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH |
| EMC Emission | Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (≧75% load) ; EN61000-3-3 |
| EMI Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), Â criteria A |
| Others | MTBF | 495.7Khrs min. MIL-HDBK-217F (25 ) |
| Dimension | 222.2*68*38.8mm (L*W*H) |
| Packing | 1Kg;12pcs/13Kg/0.58CUFT |
| Warranty | 2 years warranty |
| Datasheet | |
| Note: |
Â
- 1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4..Please refer to "DRIVING METHODS OF LED MODULE".
- 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 6. A type and C type only..
- 7.Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by theÂ
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
    - 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
 |